For installations that connect several deadbreak elbows together, the Richards R-Stack combines the connecting plug and the deadbreak elbow in one preassembled, pre-tested body. Richards says this reduces components, interfaces, stack height and inventory. It is 100% EPDM, injection molded and peroxide cured, designed, molded and tested in the USA, fully shielded (deadfront) and submersible, with an optional capacitive test point. This guide also covers the 35kV R-Stack arrester, the 15/25/28kV elbow extension adapter and the 600/900A deadbreak junctions.
R-Stack Ratings
| 15/25/28kV | 35kV |
|---|
| Max voltage (phase to ground) | 16.2 kV | 21.1 kV |
| Corona level | 26 kV | 26 kV |
| AC withstand, 1 min | 45 kV | 50 kV |
| Impulse (BIL) | 140 kV | 162 kV |
| Continuous current | 600 A aluminum, 900 A copper | 600 A aluminum, 900 A copper |
| Short-time, aluminum | 25 kA 10 cycles, 10 kA 3 s | 25 kA 10 cycles, 10 kA 3 s |
| Short-time, copper | 40 kA 10 cycles, 10 kA 3 s | 40 kA 10 cycles, 10 kA 3 s |
| Stack height with lug and contact tube | 6 3/16 in | 7 15/16 in |
| Interface | IEEE 386 Interface 11 (cable adapter Interface 17) | IEEE 386 Interface 13 (cable adapter Interface 18) |
| Fastener | One-piece, 55 ft-lbs, 3/8 in tool, lug included | One-piece, 55 ft-lbs, 3/8 in tool, lug included |
| Standards | IEEE 386, ANSI C119.4, IEEE 592 | IEEE 386, ANSI C119.4, IEEE 592 |
| Production testing | 100% partial discharge, AC withstand, impulse | 100% partial discharge, AC withstand, impulse |
Female R-Stacks ship with a loose threaded stud.
R-Stack series
| Series | Class | Notes |
|---|
| 62CB, 62CF, 62CH | 15/25kV | Listed on the 15/25/28kV R-Stack data sheet. Ordering example: 62CBN-01A, 15/25 kV 600 Amp R-Stack, M Style |
| 92CB, 92CF, 92CH | 15/25kV | Listed on the 15/25/28kV R-Stack data sheet |
| 63CH | 35kV | 35kV R-Stack, all fastener styles, per the 63RSA data sheet |
Related parts from the data sheets
| Part | Description | Class |
|---|
| P625HIP-STUD | Aluminum threaded stud | 15/25/28kV |
| P925HIP-STUD | Copper threaded stud | 15/25/28kV |
| P625HIP | Aluminum insulating plug | 15/25/28kV |
| P925HIP | Insulating plug | 15/25/28kV |
| P625CA-W | Cable adapter | 15/25/28kV |
| P635HIP-STUD | Aluminum threaded stud | 35kV |
| P935HIP-STUD | Copper threaded stud | 35kV |
| P635HIP | Aluminum insulating plug | 35kV |
| P935HIP | Copper insulating plug | 35kV |
| P635CA-W | Cable adapter | 35kV |
| P6AL-X | Aluminum compression lug | Both |
| P9CU-X | Copper compression lug | Both |
| P6ALR-X | Aluminum range-taking lug | Both |
| P7ALCU-X | Copper-top compression lug | Both |
600A 35kV R-Stack Arrester (63RSA)
Combines a deadbreak elbow surge arrester and a deadbreak connecting plug in one unit. Gapless metal oxide varistor technology in a fully shielded, submersible, peroxide-cured EPDM housing. It removes the need for 200A loadbreak arresters along with tap plugs, connecting plugs and bushing extenders. Normal duty class, tested to IEEE C62.11.
| Spec | 63RSA |
|---|
| Voltage class (phase to phase) | 35 kV |
| Corona level | 26 kV |
| Continuous current | 600 A |
| Short-time current | 10 kA 3 s, 40 kA 10 cycles |
| Fault current withstand | Up to 40 kA symmetrical per IEEE 386 (200A loadbreak arresters are rated 10 kA) |
| Interface | R-Stack 35kV 600A deadbreak male interface |
| Fastener | R-Stack, 60 ft-lb bolted connection |
| Ground lead | Pre-installed 42 in #4 AWG braided copper |
| Arrester class | Normal duty |
| Duty cycle | MCOV | 5 kA | 10 kA | 20 kA |
|---|
| 24 kV | 19.5 | 77.7 | 85.5 | 97.2 |
| 27 kV | 22.0 | 87.4 | 96.1 | 109.2 |
| 30 kV | 24.4 | 97.1 | 106.8 | 121.4 |
| 33 kV | 26.8 | 106.8 | 117.5 | 133.5 |
| 36 kV | 29.0 | 116.5 | 128.2 | 145.7 |
Discharge voltages in kV crest, 8 x 20 µs.
| Kit | Configuration | Stack height |
|---|
| 63RSA0 | Arrester stacked on elbow | 19 15/16 in |
| 63RSA1 | Arrester stacked on bushing | 15 1/4 in |
15/25/28kV Deadbreak Elbow Extension Adapter (P625DE)
Extends a cable connection to reach new equipment, such as converting live front to dead front, or to replace damaged cable and accessories. A specialized bus with a Deadbreak Elbow housing on top and a Disconnectable Joint Sleeve on the bottom. Richards JSCS cold shrink or traditional disconnectable joint sleeves can be used. The aluminum contact is overmolded with EPDM and has a factory-installed lug.
| Spec | P625DE |
|---|
| Item | P625DE0 |
| Max voltage (phase to ground) | 16.2 kV |
| Corona level | 22 kV |
| AC withstand, 1 min | 45 kV |
| Impulse (BIL) | 162 kV |
| Continuous current, aluminum | 600 A |
| Short-time, aluminum | 40 kA 10 cycles, 10 kA 3 s |
| Bus size | Equivalent to 1500 kcmil aluminum |
| Top interface | 15/25/28kV Deadbreak Elbow housing |
| Bottom interface | Disconnectable joint, IEEE 386 Interface 16 and 17 |
| Extension length | 3 11/16 in |
600/900A Deadbreak Junctions (P625JD, P925JD, P635JD, P935JD)
A junction connects multiple 600A or 900A deadbreak bushing interfaces to one common contact. It is typically installed in enclosures or mounted directly to an underground structure, such as a vault wall. EPDM, injection molded and peroxide cured, fully shielded (deadfront), and designed, molded and tested in the USA. It suits outdoor vaults, enclosures, and direct bury or submersible installations.
| 15/25kV | 35kV |
|---|
| Aluminum, 600A | P625JD | P635JD |
| Copper, 900A | P925JD | P935JD |
| Positions | 2, 3 or 4 | 2, 3 or 4 |
| Interface spacing | 4 in or 6 in | 4 in or 6 in |
| Mounting | U-straps or bracket | U-straps or bracket |
| Max voltage (phase to ground) | 15.2 kV | 21.1 kV |
| Corona level | 22 kV | 26 kV |
| AC withstand, 1 min | 42 kV | 50 kV |
| Impulse (BIL) | 162 kV | 162 kV |
| Short-time, aluminum | 25 kA 10 cycles, 10 kA 3 s | 25 kA 10 cycles, 10 kA 3 s |
| Short-time, copper | 40 kA 10 cycles, 10 kA 3 s | 40 kA 10 cycles, 10 kA 3 s |
| Interface | IEEE 386 Interface 11 | IEEE 386 Interface 13 |
| Standards | IEEE 386, ANSI C119.4, IEEE 592 | IEEE 386, ANSI C119.4, IEEE 592 |
Position count, spacing and mounting style are specified when ordering. They are not separate part numbers.
| Positions | Spacing | U-strap length | Bracket L1 / L2 / L3 |
|---|
| 2 | 4 in | 7 in | 15 / 6 / 7 in |
| 2 | 6 in | 9 in | 21 / 9 / 9 in |
| 3 | 4 in | 11 in | 19 / 8 / 11 in |
| 3 | 6 in | 15 in | 27 / 12 / 15 in |
| 4 | 4 in | 15 in | 23 / 10 / 15 in |
| 4 | 6 in | 21 in | 33 / 15 / 21 in |
Related parts from the data sheets
| Part | Description | Class |
|---|
| P625HIP-STUD | Aluminum threaded stud | 15/25kV |
| P925HIP-STUD | Copper threaded stud | 15/25kV |
| P625IC | Aluminum insulating cap | 15/25kV |
| P925IC | Copper insulating cap | 15/25kV |
| 62LCN / 62LCT, 92LCN / 92LCT | Deadbreak elbow | 15/25kV |
| P635HIP-STUD | Aluminum threaded stud | 35kV |
| P935HIP-STUD | Copper threaded stud | 35kV |
| P635IC | Aluminum insulating cap | 35kV |
| P935IC | Copper insulating cap | 35kV |
| 63LCN / 63LCT, 93LCN / 93LCT | Deadbreak elbow | 35kV |
| P6AL-X | Aluminum compression connector | Both |
| P9CU-X | Copper compression connector | Both |
| P7ALCU-X | Copper-top compression connector | Both |
| RP-II-JX | Installation instructions | Both |
Where to buy
For R-Stack, arrester and junction pricing and availability, contact Powertech Associates. In the Powertech store, see the Deadbreak Elbow Extension Adapter, Deadbreak Insulating Plug and Deadbreak Cable Adapter categories.