How to Choose a Power Design Cable Junction Pedestal

June 9, 2026
How to Choose a Power Design Cable Junction Pedestal
Need a quote?$QuoteRequest a Quote

Power Design builds fiberglass cable junction pedestals (CJPs) in single, two and three phase models, for 15, 25 and 35 kV systems with 200 A or 600 A junctions. The range is large, so picking the right model comes down to a handful of questions: how many phases, what voltage and current, how many junction points, and whether the pedestal is direct buried or padmounted.

This guide walks through those choices using Power Design's cable junction pedestal brochure and product pages, so you can narrow the list before you ask for a quote.

What is a cable junction pedestal?

A cable junction pedestal is a fiberglass enclosure that houses underground cable junctions (2, 3 or 4-way) and the parking stands used to hold cable elbows. According to Power Design's brochure, the pedestals have these common features:

  • Fire retardant 1/4 in. fiberglass construction with UV protection
  • Offered in direct buried, padmount or two piece models
  • Stainless steel or aluminum mounting assemblies for 2-point, 3-point, 4-point or multipoint junctions, 15/25/35 kV, 200/600 A
  • Stainless steel parking stands above or below the junctions, in line or on a slant
  • Optional #2 or 3/8 in. solid copper ground bar
  • Meets IEEE C57.12.28 padmounted enclosure integrity standards, and is RUS accepted
  • Standard captive penta bolt and padlocking provisions
  • A 5/8-11 lifting nut on both sides
  • Stainless steel slip joint hinges and tamper proof bolts, so the top can be removed in the full open position

Power Design lists Munsell Green, Willow Green and Light Gray as standard colors on its product pages, and special colors are available. Its brochure also lists Desert Tan.

Which model fits? Start with phase, voltage and current

ModelPhaseRatingsTop (W x D)Parking stands
CJP-10Single15/25 kV, 200 A32.5 x 22 in.2 fixed, in line with junction
CJP-11Single15/25 kV, 200 A32.5 x 22 in.2 fixed, below junction
CJP-15Single15/25 kV, 600 A (also 35 kV, 200 A)43 x 27 in.Fixed, in line
CJP-15/A, 15/BTwo15/25 kV, 200/600 A43 x 27 in.4 adjustable, above (A) or below (B)
CJP-30, 31Three15/25 kV, 200/600 A55 x 27 in.6 adjustable, above (30) or below (31)
CJP-32Three15 kV, 200 A55 x 27 in.2 fixed, in line
CJP-33Three15 kV, 200 A55 x 27 in.8 fixed, slant
CJP-35/A, 35/BThree15/25 kV 200/600 A; 35 kV versions also listed62 x 32 in.6 adjustable, above (A) or below (B)
CJP-35/SThree15/25 kV, 200/600 A62 x 32 in.8 fixed, slant
CJP-40, 41ThreeMultipoint, 15/25 kV 200/600 A; 35 kV versions also listed69 x 32 in. (some versions differ)6 adjustable, above (40) or below (41)
CJP-42Three15/25 kV, 200/600 A69 x 32 in.4 fixed, in line
CJP-43ThreeMultipoint, 15/25 kV 600 A; 35 kV versions also listed69 x 32 in.8 fixed, slant

Direct buried heights are 33, 39, 49 or 54 in. for single and two phase models, and 41, 50 or 56 in. for three phase models. Source: Power Design product pages. This table is a summary and Power Design lists several versions of each model, so confirm the drawing for the exact catalog number.

Direct buried or padmount?

The CJP models above are direct buried designs. Power Design also offers padmount versions under the CJPF name, including the CJPF-10, CJPF-11, CJPF-15/A and /B, CJPF-30 through 33, CJPF-35/A, /B and /S, and CJPF-40 through 43. The padmount single phase models are listed in 22 or 30 in. heights, and the three phase models in 30 or 41 in. heights. Top sizes vary by model, so check the drawing.

Renewable pedestals

For wind and solar collection circuits, Power Design lists renewable models, including the CJP-31D (35 kV, 600/900 A) and renewable versions of the CJP-35 and CJP-41. Options include Cooper 2 or 3-way 600/900 A junctions on 6 in. centers, or Elastimold 2, 3 or 4-way junctions on 4 in. centers.

What should you specify before ordering?

  1. Phase: single, two or three.
  2. Voltage class and current: 15/25 kV or 35 kV, and 200 A, 600 A or 900 A.
  3. Junctions: how many points (2, 3, 4 or multipoint), which junction manufacturer and how many per phase.
  4. Installation: direct buried or padmount, and the height you need.
  5. Parking stands: fixed or adjustable, above or below the junctions, in line or slant.
  6. Options: ground bar (#2 or 3/8 in. copper), ventilation louvers and color.
  7. Footprint: check the top width and depth against your excavation and clearances.

Power Design's pages do not list BIL ratings for every model. Ask for the drawing and specification before you finalize a design.

Frequently asked questions about Power Design cable junction pedestals

What are CJPs made of?

Fire retardant fiberglass, 1/4 in. thick, with UV protection, plus stainless steel and aluminum mounting hardware.

What voltages and currents are available?

15, 25 and 35 kV, with 200 A and 600 A junction arrangements, and 600/900 A on the renewable models.

Do they meet any standards?

Power Design says they meet IEEE C57.12.28 padmounted enclosure integrity standards and are RUS accepted.

How are they lifted?

With a lifting nut on each side (5/8-11 per the brochure). Power Design says they can be lifted the same way a single phase transformer is slung.

Can I get a ground bar?

Yes. A #2 or 3/8 in. solid copper ground bar is optional.

How do the doors lock?

Standard captive penta bolt and padlocking provisions. The stainless slip joint hinges let the top be removed in the full open position.

Is there a pedestal for wind or solar projects?

Yes. See the renewable models such as the CJP-31D.

Where can you get Power Design pedestals?

For questions or a quote, contact Powertech Associates and UPSC at info@powertech-upsc.com or (860) 678-8772. Send us your phase, voltage, current, junction type and installation style.

See also: Power Design padmount enclosures and Power Design primary metering options.