TE Raychem MVLC Line Covers and BCIC Overhead Covers: Raptor, Recloser, 115 kV and Animal Protection

November 3, 2026

TE Raychem MVLC Line Covers and BCIC Overhead Covers: Raptor, Recloser, 115 kV and Animal Protection

Birds, squirrels, tree limbs and flashovers cause a large share of overhead outages, and TE Raychem makes two product families to stop them: MVLC line covers for the conductor, and BCIC covers for insulators, reclosers, bus and dead ends. This guide lines up the MVLC sizes, ratings and installation tools, then the BCIC overhead covers by application. Part numbers and specs are from the TE Connectivity North America Power Transmission and Distribution product catalog (2025). For the older TE raptor cover announcement, see TE Raptor Protection Covers Prevent Bird Outages, and for the substation side of the range, see our TE wildlife and asset protection overview.

MVLC Medium Voltage Line Covers

MVLC is a wrap-around cover for overhead conductors. TE says it prevents outages caused by incidental contact from tree branches or wildlife, and that it can be applied selectively on problem spans to avoid costly conductor replacement. It is installed on energized lines with the MVLC tool, which can be operated manually or automatically.

Product sizeConductor sizeMax. conductor diameterVoltage class
MVLC-14-A/U-C(100)#6 to 3/0 kcmil0.5 in (12.7 mm)15 kV
MVLC-14-A/241-C(100)#6 to 3/0 kcmil0.5 in (12.7 mm)25 kV
MVLC-18-A/U-C(75)#2 to 397 kcmil0.75 in (18 mm)15 kV
MVLC-18-A/241-C(75)#2 to 397 kcmil0.75 in (18 mm)25 kV
MVLC-38R-A/U-C(50)#2 to 1590 kcmil1.375 in (35 mm)15 kV
MVLC-38R-A/241-C(50)#2 to 1590 kcmil1.375 in (35 mm)25 kV

The A/U part numbers are the 15 kV covers and the A/241 part numbers are the 25 kV covers. The standard package for MVLC-14 is a 330 foot (100 m) continuous spool, and for MVLC-18 it is a 247 foot (75 m) spool. TE shows the cross section of each size:

SizeWidthHeight
MVLC-141.0 in across, 0.08 in across at the base1.0 in tall
MVLC-181.0 in across1.5 in tall
MVLC-38R1.65 in across2.4 in tall

MVLC Performance

TE lists these test results for the sealed MVLC-A/U and MVLC-A/241 covers.

TestMVLC-A/UMVLC-A/241
AC withstand, dry, 1 minute15 kV min25 kV min
AC withstand, wet, 1 minute15 kV min25 kV min
AC long term withstand, dry, 4 hours8.6 kV min14.4 kV min
PropertyTest methodRequirement
30 day thermal loading (8 hr at 130 C, 16 hr off)Thermal load cycleNo MVLC deformation
Conductor ampacityAmpacity82 to 89% of bare conductor ampacity
Tensile strengthASTM D6388 MPa min (1150 psi min)
Ultimate elongationASTM D638200% min
Abrasion resistance1000 cycles, 2068 g20% max thickness loss
Low temperature impactASTM D746No cracking at -20 C
Dielectric strengthASTM D149217 kV/cm at 1.27 mm (550 V/mil min at 0.050 in)
Tracking and erosion resistanceASTM D2303 step voltage (initiate at 2.5 kV)No tracking or erosion to top surface or flame failure after 200 minutes

TE says MVLC can be installed at temperatures above 0 C (32 F). Related test reports are EDR-5308, EDR-5309, EDR-5316 and EDR-5478.

MVLC Installation Tools

Each MVLC size has its own tool. The MVLC tool kit contains the installation tool, MVLC cutters, a drainage hole punch, a hand crank and a drive nut socket, packaged in a protective bag. Hand tools are also listed for each size.

Catalog numberUse
MVLC-14-TOOL-100Installation tool for MVLC-14
MVLC-18-TOOL-03-2006Installation tool for MVLC-18
MVLC-38R-OHTOOLInstallation tool for MVLC-38R
MVLC-HAND-TOOL-14Hand tool for installing MVLC-14
MVLC-HAND-TOOL-02Hand tool for installing MVLC-18
MVLC-38R-HAND TOOLHand tool for installing MVLC-38R

BCIC Raptor Protection Covers for Insulators

TE Raychem BCIC covers protect overhead insulators to prevent outages caused by birds. They use a rugged, non-tracking, UV-resistant polymer and are designed to nest over vibration dampers. These are the standard BCIC covers, supplied in gray (G) in the catalog.

Catalog numberApplicationConductor rangeCover length (in)Insulator type / ANSIPack
BCIC-G-DPIN-795-01Double pin insulator#6 to 7954155-5, 55-6, 55-7, 56-1, 56-2, 56-36
BCIC-G-DPIN-556-01Double pin insulator#6 to 5564255-2, 55-3, 55-4, 55-56
BCIC-G-DSMPIN-795-01Double pin insulator#6 to 7954255-5, 55-6, 55-7, 56-1, 56-2, 56-36
BCIC-G-HZ-795-XLHorizontal post#6 to 79529Polymeric6
BCIC-G-HZPOR/3.5D-795-01Horizontal post#6 to 79529Porcelain, over 35 kV6
BCIC-G-HZPOR/4.5D-795-01Horizontal post#6 to 79529Porcelain, 25 to 35 kV6
BCIC-G-DE/CL-01Dead end#6 to 79527Conductor6
BCAC-G-DEADENDDead end#6 to 79526.6Porcelain or polymeric3

Related test reports: EDR-5562 and EDR-5369.

BCIC-GT Raptor Protection Covers

BCIC-GT covers do the same job with added features. TE says up to 10 feet of coverage on the conductor can be achieved when one cover and two arms are installed together, for conductor sizes #6 to 795. They install fast, and nest over vibration dampers.

Catalog numberApplicationConductor rangeLength (in)Insulator type / ANSIPack
BCIC-GT-PINPorcelain pin, post#6 to 7952055-4, 55-5, 57-26
BCIC-GT-PIN/CTVise top#6 to 79520Vise top, Hendrix6
BCIC-GT-PIN-XLPorcelain pin#6 to 7952156-1, 55-6, 55-76
BCIC-GT-DPINPorcelain pin, post#6 to 79530.555-4, 55-5, 57-26
BCIC-GT-HZHorizontal post#6 to 79521Polymeric6
BCAC-G-ARM-01Extension arm#6 to 79531Not applicable12

Related test reports: EDR-5620 (salt fog and electrical evaluation) and EDR-5609 (raptor cover mechanical and electrical evaluation).

BCIC Recloser Covers

The recloser covers have a one piece hinged design for easy, quick installation, and can be installed on energized lines. TE says the cover can be re-entered for maintenance and then reused, and that it is rated for up to 35 kV. TE notes that other Raychem products can be purchased to insulate the leads and lightning arresters.

Catalog numberColorHeight (A)Max skirt (B)
BCIC-G-ReclosercoverGray12.4 in (315 mm)7.8 in (198 mm)
BCIC-ReclosercoverRed12.4 in (315 mm)7.8 in (198 mm)
BCIC-G-Recloser-100Gray15.4 in (390 mm)6.75 in (171 mm)
BCIC-Recloser-100Red15.4 in (390 mm)6.75 in (171 mm)
BCIC-G-Recloser-200Gray14.5 in (368 mm)8.5 in (216 mm)
BCIC-G-Recloser-200SGray18.3 in (465 mm)8.3 in (211 mm)
BCIC-Recloser-200SRed18.3 in (465 mm)8.3 in (211 mm)
BCIC-5D/8/11Red9.0 in (228 mm)4.8 in (122 mm)

Pack quantities are in the catalog.

BCAC Distribution Covers for Animal Protection

BCAC covers are for terminations, reclosers, lightning arresters and fuse cutouts. TE says extensive testing has shown the cover will not damage or deteriorate the terminations, that they can be installed on energized equipment, and that they are secured to the stud and the conductor to insure protection in high winds. The BCAC-G-CUTOUT is hot-stickable and clips onto cutout insulators between the first and second skirt.

Catalog numberHardware
BCAC-P-IC-5D/6Transformer bushing
BCAC-G-4D/13-2Terminations
BCAC-G-5D/8-01Transformer bushing
BCAC-G-AR-5D-2Ohio Brass arrester
BCAC-G-AR-4D-2TE arrester
BCAC-G-AR-3.75D-2Cooper arrester
BCAC-G-CUTOUT-100-01-B12Fuse cutout switch, 100 A, porcelain style
BCAC-G-CUTOUT-100-P2-B12100 A, polymeric (Hubbell and Cooper style)
BCAC-G-CUTOUT-FTFuse cutout switch, 200 A, porcelain style
BCAC-G-CUTOUT-FT-PFuse cutout switch, 200 A, polymeric style

Related test reports: EDR-5407 (bushing covers), EDR-5569 (BCAC-P-IC), EDR-5571 (BCAC-AR) and EDR-5573 (cutouts).

BCIC-115-PH Transmission Flashover Protection Cover

BCIC-115-PH is for 115 kV transmission lines. TE says it works on both porcelain disc and polymeric insulator designs, and its design lets the cover rest on the lowest insulator for porcelain i-string designs. It can be used on energized or de-energized installations.

Catalog numberLengthHeightInsulator rangeApplication
BCIC-115-PH74 in (1879.6 mm)15 in (381 mm)9 to 12 in (229 to 305 mm)Main cover
BCIC-Collar-50/280-5-BAdapter collar for polymeric installations

BCIC-AFD-01 Avian Flight Diverter

The BCIC-AFD-01 is designed to prevent bird collisions with power lines on distribution and transmission lines. It uses high reflectivity and glow-in-the-dark appliques, is hot-stickable and removable, and can be used on energized or de-energized installations.

Catalog numberDescriptionDimensions W x HConductor sizePack
CU7208-000BCIC-AFD-014 x 3.5 in (102 x 89 mm)#6 to 79510

Related test report: EDR-5536, Rev. A.

BCIC-Angle Bus Covers

The BCIC-Angle cover is a modular, wrap-around design for retrofit insulation on 3 to 4 inch angle busbars, when existing equipment cannot be dismantled. TE says it provides flashover protection up to 35 kV, is suitable for indoor and outdoor use, and that overlapping sections give increased busbar coverage. TE lists it with the substation covers, so we include it here for reference.

Catalog numberColorBusbarSupplied lengthPack
BCIC-ANGLE-4X48Red3 to 4 in (75 to 100 mm)4 ft6 pieces
BCIC-G-ANGLE-4X48Gray3 to 4 in (75 to 100 mm)4 ft6 pieces

Related test reports: EDR-5562, EDR-5369 and EDR-5594.

How to Choose

ProblemTE product
Tree limbs or wildlife touching the conductorMVLC line cover (14, 18 or 38R by conductor size)
Birds on pin, post or dead end insulatorsBCIC covers or BCIC-GT covers
Animals on a recloserBCIC recloser covers
Animals on bushings, arresters, terminations or cutoutsBCAC distribution covers
Flashovers on 115 kV linesBCIC-115-PH
Bird collisions with the lineBCIC-AFD-01 flight diverter

Frequently Asked Questions About MVLC and BCIC Covers

How do I pick the MVLC size?

By conductor size. MVLC-14 fits #6 to 3/0 kcmil, MVLC-18 fits #2 to 397 kcmil and MVLC-38R fits #2 to 1590 kcmil.

What is the difference between the A/U and A/241 MVLC?

The A/U covers are rated 15 kV and the A/241 covers are rated 25 kV.

Can MVLC be installed on energized lines?

Yes. TE says installation on energized lines is possible with the MVLC tool.

What is the lowest temperature MVLC can be installed at?

TE says MVLC can be installed at temperatures above 0 C (32 F).

Does MVLC change the conductor rating?

TE lists conductor ampacity with the cover at 82 to 89% of bare conductor ampacity.

What is the difference between BCIC and BCIC-GT?

Both protect insulators from birds. TE says the GT covers can give up to 10 feet of coverage on the conductor when one cover and two arms are installed together.

Can BCIC covers go on a recloser?

Yes. TE lists dedicated BCIC recloser covers, rated up to 35 kV, that can be re-entered and reused.

How do I pick the BCIC cover for my insulator?

Match the insulator type, ANSI class and conductor range in the tables above. Contact Powertech Associates and we will match it for you.

Where to Buy MVLC and BCIC Covers

Powertech Associates supplies TE Connectivity Raychem wildlife and asset protection products. Send us your conductor size, insulator type and voltage class, and we will match the cover and the tool. Order online: BCIC-G-Recloser-100 recloser cover, BCAC-G-CUTOUT-100-P2-B12 fuse cutout cover or BCAC-P-IC-5D/6 bushing cover. For the MVLC covers and tools, the other BCIC covers and the rest, contact Powertech Associates at info@powertech-upsc.com or (860) 678-8772.

Last updated: November 2026.

Interested in this product?

Contact us, request a quote, or order online.