Power Design Switchgear: Padmount Recloser and 600V Secondary Terminations

October 6, 2026
Power Design Switchgear: Padmount Recloser and 600V Secondary Terminations
Need a quote?$QuoteRequest a Quote

Power Design Inc. builds three switchgear products for utilities: a padmount recloser enclosure, a padmount 600 V secondary termination, and a wall-mount 600 V secondary termination. The recloser unit is for 15 kV and 25 kV systems. The two terminations are for 600 V service. All three are listed under Switchgear on Power Design's site.

Which Power Design switchgear do you need?

ProductVoltageRatingMountingUsed for
Padmount Recloser15 kV and 25 kV, 95 kV or 125 kV BILDepends on the recloser installedFiberglass padmount enclosure on a free-standing galvanized frameHousing a three-phase recloser, with or without a group-operated loadbreak switch
Padmount Secondary TerminationUp to 600 VCopper bus 1,600 to 4,300 A, aluminum bus 1,300 to 2,900 A, or 4,000 A set-screw connectorsPadmount fiberglass enclosureTerminating secondary cables from a transformer or switchgear
Wall-Mount 600V Secondary Termination600 V, three-phaseUp to 4,000 AWall-mounted galvanized steel frameHeavy-duty secondary termination on a wall

Padmount recloser

Power Design's padmount recloser is a three-phase unit sold with or without a group-operated loadbreak disconnect switch. With the switch, it gives complete isolation and a visible break for field operation. A Lexan viewing window lets the crew confirm switch position.

The fiberglass enclosure installs over a custom, free-standing, hot-dipped galvanized frame that supports the disconnect switch. Because the enclosure can be mounted or removed on its own, maintenance and field installation are simpler.

ItemPower Design says
Voltage15 kV and 25 kV ratings, 95 kV or 125 kV BIL. Designed for 25 kV systems with 125 kV BIL, and compatible with 15 kV or 25 kV rated reclosers
SwitchingOptional group-operated loadbreak disconnect switch with a Lexan viewing window for visible break
EnclosureFiberglass, outdoor, weatherproof, with stainless steel hardware
ConstructionFire retardant and corrosion resistant
FrameFree-standing, hot-dipped galvanized steel, so the enclosure comes off for access to the equipment
ControlRecloser control module mounted on the outside of the enclosure
Control powerControl power transformer included, supplying 120 VAC to the recloser control
DurabilityFiberglass laminate guaranteed for 25 years against degradation under normal use

Power Design lists four drawings (PS4-86-4614, PS4-86-4834, PS4-86-4871 and PS4-86-3672) and a Padmount Recloser with Group Operated Switch sheet on the product page. Ask us if you need them. Power Design also says to contact its sales department for special requirements or custom configurations.

Padmount secondary termination

This is a fiberglass padmount enclosure with a free-standing welded aluminum steel frame that holds the secondary termination bus. The aluminum support bars are removable, which makes cable connection easier.

OptionRating
High-conductivity copper bus1,600 to 4,300 A
Aluminum bus1,300 to 2,900 A
22-position aluminum set-screw connectors, #2 to 750 MCM4,000 A
Tap-source-tap (T-S-T) configurationHigher capacities, up to 7,740 A

Power Design bases these ratings on a source-to-tap (S-T) configuration. Its T-S-T layout puts copper busbars in the center with taps at each end for efficient distribution. Power Design's product description says up to 7,740 A for T-S-T, while its feature list says up to 7,400 A, so confirm the number for your configuration before you specify it.

Other features Power Design lists:

  • Fire-retardant fiberglass with a UV-stabilized gel coat
  • Resistant to temperature, weather and corrosive conditions, and virtually maintenance free
  • Copper or aluminum bus bars, typically 17 two-hole positions per phase plus neutral, with custom bus bar sizes available
  • 22 or 30 position aluminum set screw connectors for #2 to 750 MCM conductors
  • Copper ground connector included

The product page lists drawings PS4-44-2222, PS2-44-1582, MB-40-30-1766 and MB-40-22-4124, an amperage table for aluminum and copper bus, and an IEEE C57.12.28 certification document. Confirm that the certification covers the model you are ordering.

Wall-mount 600V secondary termination

The wall-mount version is a three-phase, 600 V assembly rated up to 4,000 A for heavy-duty distribution service.

ItemPower Design says
Voltage and phase600 V, three-phase
Maximum currentUp to 4,000 A
FrameGalvanized steel, wall-mounted
Cover1/4 in. clear Lexan (polycarbonate) safety cover
InsulatorsFiberglass GPO-3 angle insulators
ConnectorsAluminum set-screw, 22 or 30 position, #2 AWG to 750 MCM
GroundingCopper grounding connector included

How do I choose?

  • Need to isolate and protect a 15 or 25 kV feeder? The padmount recloser enclosure houses the recloser and, if you add it, a group-operated switch with visible break.
  • Terminating 600 V secondary cables at ground level? Use the padmount secondary termination. Pick copper or aluminum bus, or set-screw connectors, by the current you need.
  • Terminating 600 V secondary cables on a wall? Use the wall-mount termination, up to 4,000 A.

Tell us the voltage, current, conductor size and mounting, and we will help you match the right unit. For other Power Design enclosures, see the padmount enclosures guide, the primary metering guide and the cable junction pedestal guide.

Frequently asked questions

What switchgear does Power Design make?

A padmount recloser, a padmount 600 V secondary termination and a wall-mount 600 V secondary termination.

What voltages is the padmount recloser for?

Power Design lists 15 kV and 25 kV ratings with 95 kV or 125 kV BIL. It is designed for 25 kV systems with 125 kV BIL and is compatible with 15 kV or 25 kV rated reclosers.

Does the recloser come with a disconnect switch?

The group-operated loadbreak disconnect switch is optional. Confirm what is included when you order.

What is the maximum current of the secondary terminations?

The wall-mount unit goes up to 4,000 A. The padmount unit depends on the bus: copper 1,600 to 4,300 A, aluminum 1,300 to 2,900 A, and higher in a T-S-T configuration.

What conductor sizes do the set-screw connectors take?

#2 AWG to 750 MCM, in 22 or 30 position configurations.

Is the fiberglass warranted?

Power Design guarantees the recloser enclosure's fiberglass laminate for 25 years against degradation under normal use. Its limited warranty document has the full terms.

Where can I buy Power Design switchgear in New England or New York?

Powertech Associates represents Power Design and serves utilities across New England and New York State. Tell us what you need and we will get you a quote. Contact us at info@powertech-upsc.com or (860) 678-8772.

Last updated: November 2026.