TE Raychem BCAC and BCAC-IC Bushing Covers: Sizes, Inspection Covers and Regulator Kits

November 14, 2026

TE Raychem BCAC and BCAC-IC Bushing Covers: Sizes, Inspection Covers and Regulator Kits

Animals that climb onto a transformer or regulator bushing can bridge the connection and cause an outage. TE Raychem makes two covers for that job. The BCAC is a solid bushing cover. The BCAC-IC adds an inspection feature so crews can see the connection and oil levels. Both are made for bushings in the 15 to 35 kV range. Specs are from TE's Raychem Wildlife & Asset Protection catalog (2019). For the overhead lines side, see TE Raychem MVLC and BCIC overhead covers, and for the full line see the TE Raychem Wildlife and Asset Protection overview.

BCAC and BCAC-IC at a Glance

BCACBCAC-IC
What it isBushing connection animal coverBushing connection inspection substation cover
Bushing rangeBushings from 15 to 35 kVEquipment up to 35 kV
InspectionNo inspection feature listedVisual inspection of the connection and oil levels
Conductor exitNot listedConductors and leads exit through the cover, with top and side exits so you do not need to trim
ClosureFast and easy installationRobust latching and hinging mechanisms
ColorsRed or grayRed or gray
One cover perOne insulatorNot stated

BCAC Sizes

Dimensions are in inches, with mm in parentheses.

Catalog numberMax shed diameterCover heightColor
BCAC-5D/8-01 (B12)4.8 (122)8.0 (203)Red
BCAC-7D/10-01 (B6)6.8 (172)10.5 (266)Red
BCAC-8D/14-01 (B6)8.0 (203)14.0 (355)Red
BCAC-G-5D/8-01 (B12)4.8 (122)8.0 (203)Gray
BCAC-G-7D/10-01 (B6)6.8 (172)10.5 (266)Gray
BCAC-G-8D/14-01 (B6)8.0 (203)14.0 (355)Gray
BCAC-BYPASS-01 (B1)6.8 (172)10.6 (266)Red
BCAC-BYPASS-02 (B1)8.0 (203)14.0 (355)Red

The catalog notes that the BCAC covers are also kitted for voltage regulator applications. The kit includes two bushing covers and a center arrester cover. The standard package is 12 or 6 units per box, depending on cover size. One BCAC installs on one insulator.

BCAC-IC Sizes

Catalog numberStd packColorInsulator core rangeInsulator shed rangeCover diameterCover height
BCAC-IC-5D/6 (B6)6Red1.5 to 3.5 (38 to 89)2.5 to 5.0 (63 to 127)5.00 (127)6 (152)
BCAC-IC-7D/12 (B6)6Red3.0 to 4.87 (76 to 124)3.75 to 7.00 (95 to 178)7.00 (178)12 (305)
BCAC-IC-8D/18 (B6)6Red3.5 to 6.25 (90 to 160)4.00 to 8.00 (100 to 200)8.00 (200)18 (455)
BCAC-IC-10.5D/20 (B6)6Red3.5 to 8.5 (90 to 215)6 to 10.5 (150 to 267)10.75 (273)20 (508)
BCAC-G-IC-5D/6 (B6)6Gray1.5 to 3.5 (38 to 89)2.5 to 5.0 (63 to 127)5.00 (127)6 (152)
BCAC-G-IC-7D/12 (B6)6Gray3.0 to 4.87 (76 to 124)3.75 to 7.00 (95 to 178)7.00 (178)12 (305)
BCAC-G-IC-8D/18 (B6)6Gray3.5 to 6.25 (90 to 160)4.00 to 8.00 (100 to 200)8.00 (200)18 (455)
BCAC-G-IC-10.5D/20 (B6)6Gray3.5 to 8.5 (90 to 215)6 to 10.5 (150 to 267)10.75 (273)20 (508)

The BCAC-IC bypass versions are single-pack kits.

Catalog numberMax shed diameterCover heightColor
BCAC-IC-BYPASS-01 (B1)7.0 (178)12.00 (305)Red
BCAC-G-IC-BYPASS-01 (B1)7.0 (178)12.00 (305)Gray

How to Choose a Bushing Cover

StepWhat to do
1. Measure the bushingFor the BCAC, measure the maximum shed diameter. For the BCAC-IC, measure the insulator core and the shed diameter.
2. Pick the typeBCAC if you only need animal protection. BCAC-IC if crews need to see the connection and oil level.
3. Match the sizeChoose the size whose range covers your bushing.
4. Pick the colorRed or gray.
5. RegulatorsFor voltage regulators, ask about the BYPASS kits. The catalog says the kit has two bushing covers and a center arrester cover.

Test Reports

ProductTE test reports
BCACEDR-5339, EDR-5407, UVR-8209
BCAC-ICEDR-5514, UVR-8209

Frequently Asked Questions About BCAC and BCAC-IC Covers

What is the difference between BCAC and BCAC-IC?

The BCAC is a bushing cover for animal protection. The BCAC-IC adds visual inspection of the connection and oil levels, with latching and hinging mechanisms and conductor exits at the top and side.

What voltage are they for?

TE lists the BCAC for bushings from 15 to 35 kV, and the BCAC-IC for equipment up to 35 kV.

Do I need to trim the conductor to fit the BCAC-IC?

No. TE says it has top and side exits for the conductor, so you do not need to trim.

Can I use them on a voltage regulator?

TE says the BCAC covers are also kitted for voltage regulator applications. The kit includes two bushing covers and a center arrester cover.

How many covers per bushing?

One BCAC installs on one insulator.

What colors are available?

Red and gray in all sizes listed.

Where to Buy Bushing Covers

Powertech Associates supplies TE Raychem wildlife and asset protection products. Order online: BCAC-8D/14-01, BCAC-G-5D/8-01, BCAC-IC-8D/18, BCAC-G-IC-5D/6, BCAC-G-IC-7D/12, BCAC-G-IC-8D/18 or BCAC-G-IC-10.5D/20. To match a cover to your bushing or ask about bypass kits, contact Powertech Associates at info@powertech-upsc.com or (860) 678-8772.

Last updated: November 2026.

Interested in this product?

Contact us, request a quote, or order online.