Wildlife-Induced Outages and V0+ Material: What TE Says Makes a Protection Cover Last

October 28, 2026

Wildlife-Induced Outages and V0+ Material: What TE Says Makes a Protection Cover Last

Wildlife causes outages in two ways, and the cover or guard that fixes them is only as good as the material it is made from. This guide covers what TE says about how bridging and guano flashover happen, the material tests TE says a protection product should meet, and what TE says about its newer V0+ material. It draws on TE's 2015 wildlife white paper (INMR Congress 2015, by Don Barrett) and a May 2023 TE press release. For the products themselves, see the TE Raychem Wildlife and Asset Protection overview and our MVLC and BCIC overhead covers guide.

Two Ways Wildlife Causes Outages

MechanismHow it happensWhere it happens
BridgingA bird or animal touches two phases, or a phase and ground, and creates a short circuit. The paper says it usually kills the animal, and repeated events can build up damage such as burned conductor strands.Mostly medium voltage systems (typically under 36 kV), in substations and on overhead lines
Guano pollution flashoverBird guano builds up on an insulator over weeks or months of dry weather. When mist, fog or rain returns, the dried guano turns semi-liquid, surface resistance drops and flashover can result. The paper also describes guano streamers, a liquid streamer of up to 2 m that can short an air gap.Mostly overhead line insulators, across all voltage ranges up to transmission levels; less often in substations

The paper says the guano problem it describes is separate from the airborne contaminants, like salt in coastal areas, that the term pollution flashover usually means.

Clearances TE Calls Vulnerable

LocationClearance in the paper
Medium voltage substationUp to 40 cm between phases or phase and ground is considered vulnerable to wildlife bridging, and up to about 1 m where large animals such as snakes, monkeys or large birds of prey are the problem
Overhead line, conductor to conductorAbout 1 m
Overhead line, cross arm to conductorTypically 30 to 40 cm. The paper calls this the most common failure mode, since medium and large birds bridge it during landing or takeoff.

Material Tests TE Says a Protection Product Should Meet

TE's paper says that on day one almost any solution works to some degree, but the one that matters keeps working maintenance free for the life of the equipment, often 20 years or more in heat, cold, severe weather, UV and bird guano. It lists these minimum criteria. The values are as printed in the paper.

PropertyStandardResult listedWhy it matters, per TE
Tracking and erosion resistanceASTM D23031 hour at 3.00 kVMost products sit between phase and ground and see leakage currents
UV stabilityASTM G154100% at 75k hoursLong-term exposure in climate extremes
Thermal enduranceASTM D638105 C continuousEndure high ambient and current temperatures without distortion or melting
Ultimate elongationASTM D638300% targetKeeps a high degree of flexibility
Dielectric strengthASTM D14913 kV/mmMinimum insulation value

TE says the material should perform without electrical or mechanical breakdown for over 30 years, and names its Raychem family of polymers, on the market since the 1960s, as a material range that has done so. The paper shows failures by tracking, UV and erosion when materials fall short.

What TE Says V0+ Adds

In May 2023, TE announced V0+, described as a new-to-market formulation for the Raychem wildlife and asset protection range. TE says it builds on Raychem materials that have shown excellent tracking and erosion resistance testing (TERT) performance and proven longevity.

V0+ claimTE statement
UV and thermalUp to 5,000 hours of UV and thermal endurance performance
Tracking and erosionHigh TERT performance, above 180 minutes by the STEP method with abrasion
FlammabilityV0 compliance according to UL94
What is newCustomers do not have to choose between high TERT performance and V0. They get both in one material.
Service lifeTE says the Raychem WAP portfolio is designed and optimized for over 40 years in service
ProductsTE says V0+ applies to its wildlife and asset protection insulating covers and barriers for overhead lines and substations. The announcement does not list part numbers or voltage ratings.

The 2015 paper and the 2023 announcement use different test descriptions, so their figures are not directly comparable. Ask TE for the test report on the product you plan to buy. Our store lists the BCAC-G-CUTOUT-100-P2-B12 fuse cutout cover as a V0+ version.

How TE Says to Apply Protection

GuidanceTE paper
Where to insulateInsulate vulnerable bare metal, typically up to 30 cm further along the busbar or line than the farthest known fault location. Local knowledge comes first.
Which sideFor phase to ground bridging it is more common to insulate the live side, but insulating the grounded side is also acceptable
FormsHeat shrink, cold applied covers, or a combination
Field cuttingCovers made from a cross-linked polymeric material will not propagate splits if they are roughly cut in the field
GuanoUse a high performance, UV stable polymer shield secured at the top of the insulator string. Rain then washes the guano away from the string.
GoalLet wildlife keep its access while preventing electrical breakdown
CostThe paper says installing protection should cost considerably less than the outage it prevents, and uses about $10k per outage in the U.S. as an average, with a range of $1k to over $1 million

Examples in the Paper

CaseWhat TE did
White stork nestsWraparound cover on bare fittings and wraparound sleeving on the conductor about 1.5 m away from the nest in both directions
Crow nest on a 66 kV lineConductor sleeve plus a wraparound connection cover
Germany, 10 and 20 kV mast topsInsulation covers about 1.4 m long, fitted by cable ties or with hot sticks, with transparent versions for aerial inspection
Guano on an insulator stringA UV stable shield over the string
Croatia urban substationHeat shrink tubing on busbars and removable cold applied covers on connections, against 40 cm gaps bridged by cats and birds
Athens substationCovers, wraparound sleeving and circular barriers that stop cats climbing the insulator
South Africa substationHeat shrink tubes and wraparound covers across the site, after 12 flashovers in the first year caused by monkeys, even where clearances were about 1 m
20 kV substation in GermanyWraparound covers field cut to the geometry, with a cut-out for an earth clamp

Which TE Guide Covers What

EquipmentGuide
Overhead conductors, insulators, reclosersMVLC and BCIC overhead covers: guide
Substation bushingsBCAC and BCAC-IC: guide
Bus insulatorsBISG squirrel guards: guide
Substation leads, jumpers and busMVCC, MVFT, BCIC-Angle, HVIS, HVBC and RRBB: guide
Busbar tape and tubingSee HVBT and BBIT and BPTM

Frequently Asked Questions About Wildlife Protection Materials

What is V0+?

TE's name for a new formulation in its Raychem wildlife and asset protection range, announced in May 2023. TE says it combines high tracking and erosion resistance with UL94 V0 flammability compliance in one material.

What does V0 mean?

TE states V0 compliance according to UL94, a flammability classification.

How long does TE say its WAP products last?

TE says the Raychem WAP portfolio is designed and optimized for over 40 years in service. The 2015 paper targets over 30 years without breakdown.

Why does material matter for a wildlife cover?

TE says most products sit between phase and ground and see leakage currents, so tracking and erosion resistance, UV stability and thermal endurance decide whether a cover keeps working for decades.

What causes guano flashover?

Dried guano on an insulator turns semi-liquid when mist, fog or rain returns, which lowers the surface resistance. Guano streamers up to 2 m can also short an air gap.

How far should I insulate?

TE's paper says typically up to 30 cm beyond the farthest known fault location, with local knowledge taken into account.

Which products use V0+?

The announcement does not list part numbers. Ask Powertech Associates or TE to confirm a specific product.

Where to Buy TE Wildlife and Asset Protection Products

Powertech Associates supplies TE Raychem wildlife and asset protection products. Browse the TE Wildlife Asset Protection category, or contact Powertech Associates at info@powertech-upsc.com or (860) 678-8772 to match a product and material to your equipment.

Last updated: November 2026.

Interested in this product?

Contact us, request a quote, or order online.